(广州健仑生物科技有限公司是集研制开发、销售、服务于一体的优良企业,公司产品涉及临床快速诊断试剂、食品安全检测试剂,违禁品快速检测,动物疾病防疫检测试剂,免疫诊断试剂、临床血液学和体液学检验试剂、微生物检验试剂、分子生物学检验试剂、临床生化试剂、有机试剂等众多领域,同时核心代理Panbio、FOCUS、Qiagen、IBL、CORTEZ、Fuller、Inbios、BinaxNOW、LumuQuick、日本富士、日本生研等多家有名诊断产品集团公司产品,致力于为商检单位、疾病预防控制中心、海关出入境检疫局、卫生防疫单位,缉毒系统,戒毒中心,检验检疫单位、生化企业、科研院所、医疗机构等机构与行业提供*、高品质的产品服务。此外,本公司还开展食品、卫生、环境、药品等多方面的第三方检测服务。)
军团杆菌,系需氧革兰氏阴性杆菌,以嗜肺军团菌zui易致病。现已提出了超过30种军团杆菌,至少19种是人类肺炎的病原。其中zui常见病原体为嗜肺军团菌(占病例的85%~90%),其次是L.micdadei(占5%~10%),再次是L.bozemanii和L.dumoffii.此类细菌形态相似,具有共同的生化特征,引起类似疾病。
军团菌病是由军团菌属细菌引起的临床综合征。1976年美国费城召开退伍军人大会时暴发流行而得名。病原菌主要来自土壤和污水,由空气传播,自呼吸道侵入。临床表现类似肺炎。
主要用途:用于检测尿样中嗜肺军团菌血清型1抗原,以支持军团菌感染的诊断。
产品规格:20T/盒
存储条件:2-30℃
嗜肺军团菌酶联免疫法检测试剂盒(进口)
我司还提供其它进口或国产试剂盒:登革热、疟疾、西尼罗河、立克次体、无形体、蜱虫、恙虫、利什曼原虫、RK39、汉坦病毒、深林脑炎、流感、A链球菌、合胞病毒、腮病毒、乙脑、寨卡、黄热病、基孔肯雅热、克锥虫病、违禁品滥用、肺炎球菌、军团菌、化妆品检测、食品安全检测等试剂盒以及日本生研细菌分型诊断血清、德国SiFin诊断血清、丹麦SSI诊断血清等产品。
欢迎咨询
欢迎咨询2042552662
【产品介绍】
货号 | 产品名称 | 产品描述 | 产品规格 | 保存条件 |
JL-ET01 | 免疫捕获诺如病毒检测试剂盒 | 用于检测粪便标本中的诺如病毒抗原,以支持诺如病毒感染的诊断。 | 20T/盒 | 2-30℃ |
JL-ET02 | 免疫捕获军团菌检测试剂盒 | 用于检测尿样中嗜肺军团菌血清型1抗原,以支持军团菌感染的诊断。 | 20T/盒 | 2-30℃ |
JL-ET03 | 免疫捕获肺炎链球菌检测试剂盒 | 用于检测尿标本中的肺炎链球菌抗原,以支持肺炎链球菌感染的诊断。 | 20T/盒 | 2-30℃ |
二维码扫一扫
【公司名称】 广州健仑生物科技有限公司
【】 杨永汉
【】
【腾讯 】 2042552662
【公司地址】 广州清华科技园创新基地番禺石楼镇创启路63号二期2幢101-3室
【企业文化】
军团菌藏在空调中
军团病为什么会在退伍军人中暴发流行呢?为了弄清军团病是怎样传播的,费城的流行病学专家对当时疾病的流行进行了详细的调查。
他们发现,军团病不存在人→人的传播方式,因为与病人密切接触的人,甚至住在同房间的人中无一人被传染。尽管大会提供了两次会餐,但大多数进餐者未发病,而没有进餐者却生了病。同时也找不到因水源、饮料或啤酒引起疾病的证据。科学家们又想到了吸烟,可是吸烟和不吸烟的人都有发病,而未见当地吸同种牌子的吸烟人中有发病现象。由于当时是夏季,科学家们自然考虑到疾病的流行是否与昆虫叮咬有关。但病人都反映未被昆虫叮咬,甚至没有接触过鸟类和哺乳动物,也未接收共同的礼品或纪念品。
是什么原因引起的疾病流行呢?科学家开始对参会代表的居住环境进行了调查。大会代表分别住在当地的A、B、C三个旅馆里,大会总部设在A旅馆,从病例人群分布和大会活动情况分析,发病者多是到过A旅馆的前厅和第14楼招待室,或者从这两个地方走过。这说明,这两个地方的空气中有共同的致病菌。
那么,空气中的病菌又是哪里来的呢?又经过一番调查,人们终于发现,这些致病菌藏在旅馆的空调系统中。
军团病流行有特定原因
军团病易发季节多集中在夏末秋初。军团菌是一种在自然界中抵抗力很强的细菌,它主要在水中生存,在河水、溪水、湖水、池塘水中都可以分离到这种细菌。军团菌的生命能力也很强,在自来水中能生存1年以上。因此,它经常污染空调系统的水、水塔水、沐浴喷头,甚至污染矿泉水。1997年-1999年,我国的流行病专家调查了14家四星级以上的饭店,结果在85.7%的空调冷却塔中检测出军团菌。
Legionella hidden in air conditioners
Why Legionnaires outbreak among the veterans popular it? To understand how Legionnaires' Disease spread, Philadelphia epidemiologists conducted a detailed survey of the prevalence of the disease at the time.
They found that there was no human-to-human transmission of Legionnaires' Disease because none of those who were in close contact with the patient and even those who lived in the same room were infected. Although the meeting provided two meals, most diners did not get sick, but none of them dined. Also can not find evidence of illness caused by water, beverages or beer. Scientists also think of smoking, but smoking and non-smoking people have the incidence, but did not see the local inhalation of the same brand of smoking among the incidence phenomenon. Since it was summer, scientists naturally considered whether the epidemic was related to insect bites. However, patients reported no bites from insects or even contact with birds and mammals, nor did they receive common gifts or souvenirs.
What causes the disease epidemic? Scientists began a survey of the living environment of the participants. Congress representatives were living in the local A, B, C three hos, the General Assembly headquarters in the A Ho, the distribution of the case population and the activities of the General Assembly, the incidence was mostly A ho lobby and reception on the 14th floor Room, or walk from these two places. This shows that there is a common pathogen in the air in both places.
So, where is the germs in the air? After some investigation, people finally found that these pathogens hidden in the ho's air-conditioning system.
Legionella disease has a specific reason
Legionnaires disease season more concentrated in late summer and early autumn. Legionella is a highly resistant bacterium in nature that lives predominantly in water and can be isolated in rivers, streams, lakes and pond waters. Legionella is also very strong in life and can survive in tap water for more than one year. Therefore, it often pollutes air-conditioning system water, water tower, shower nozzle, and even contaminated mineral water. From 1997 to 1999, epidemiologists in our country surveyed 14 hos with four or more stars, resulting in the detection of Legionella bacteria in 85.7% of air-conditioning cooling towers.